The charge should disconnect the load OUT terminal on the positive and negative cannot be wrong, please according to specifications, otherwise, it will damage directly.
The first time you access the battery, it may no voltage between the output OUT+ and OUT-, then access 5V voltage charge your energy can activate the protection circuit, and the battery from the B + B-, then draw a line on the short open also need to be recharged to activate the protection circuit. Note that the charger must be able to output 1A or more to do when using a mobile phone charger input, or may not charge
+ MICRO USB female and next - pads for the power input, access 5V. B + positive then the lithium battery, B- then negative lithium batteries. OUT+ and OUT- connected to the load, such as positive and negative electrodes connected mobile booster plate or other loads.
Connect the battery to the B + B-, inserted into the USB female mobile phone charger, the red light is being charged, the green light to full.
NOTE: Due to the nature and characteristics of lithium-ion batteries Addicore is not responsible or liable for any damages, malfunction, injuries, fire, burns, or any other consequences or results that may occur with incorrect or correct use of this module or any battery, device, or item this module is used with, including following or using any instructions, guidance, or direction of any kind from Addicore or others. By purchasing this product you accept the preceding.